Magnet Wire Gauge Explorer

The American Wire Gauge is a geometric series: 39 steps between AWG 36 and AWG 0000, every six gauges halving the diameter. Slide through the gauges to see the wire magnified, its resistance per metre and how much current it may safely carry.

Parameters

Wire gaugeAWG
Allowed current densityJJ2–3 for buried windings, 4–6 for open airA/mm²
TemperatureTT°C
enamel 15 µmcopper Ø 0.255 mm0.1 mm at this scalemagnification ×808
Fig. 3AWG 30 magnet wire in section, heavy-build enamel.
AWG 30
Bare diameterdd0.255 mm
Enamelled Ødid_i0.285 mm
Copper areaAA0.0509 mm²
Resistance339 mΩ/m
Per 1000 ft103 Ω
Length per kg2,192 m
Turns / cm35.1
Max currentImaxI_{max}153 mA
Diameter10 mil

Resistance per metre across the gauge range

05101520253035400.0010.010.1110AWG 30AWGΩ per metre

Reference table (tap a row)

AWGØ bare mmØ enam. mmΩ / mTurns/cmI @ J
141.631.710.008285.846.24 A
151.451.530.01046.554.95 A
161.291.360.01327.343.93 A
171.151.220.01668.233.11 A
181.021.080.02099.222.47 A
190.9120.9680.026410.31.96 A
200.8120.8640.033311.61.55 A
210.7230.7720.042131.23 A
220.6440.690.05314.5977 mA
230.5730.6160.066816.2774 mA
240.5110.5510.084218.1614 mA
250.4550.4930.10620.3487 mA
260.4050.4410.13422.7386 mA
270.3610.3950.16925.3306 mA
280.3210.3540.21328.3243 mA
290.2860.3170.26831.5193 mA
300.2550.2850.33935.1153 mA
310.2270.2560.42739.1121 mA
320.2020.230.53843.596.1 mA
330.180.2070.67948.376.2 mA
340.160.1870.85653.660.4 mA
350.1430.1681.0859.447.9 mA
360.1270.1521.3665.838 mA
370.1130.1381.7272.730.1 mA
380.1010.1252.1680.223.9 mA
390.08970.1132.7388.319 mA
400.07990.1033.449715 mA
410.07110.0944.3410611.9 mA
420.06330.08595.471169.45 mA
430.05640.07876.91277.5 mA
440.05020.07228.71385.95 mA

How it works

Theory · assumptions · formulas

The geometric series

AWG was defined by fixing gauge 36 at 0.005 inch and gauge 0000 at 0.46 inch, with 39 equal ratios in between:

dn=0.127 mm×9236−n39d_n = 0.127\ \mathrm{mm} \times 92^{\frac{36-n}{39}}

Each step changes the diameter by 921/39≈1.122992^{1/39} \approx 1.1229 and the area by about 1.261. Three gauges therefore double the area (halve the resistance), and six gauges halve the diameter.

Resistance and mass

Rℓ=ρTA,ℓm=1δCu A\frac{R}{\ell} = \frac{\rho_T}{A}, \qquad \frac{\ell}{m} = \frac{1}{\delta_{Cu}\,A}

with δCu=8960 kg/m3\delta_{Cu} = 8960\ \mathrm{kg/m^3}. Magnet wire is bought by weight, so the length per kilogram tells you how many spools a winding will consume.

Current rating

The safe current is set by heating, not by the wire itself. Expressed as a current density Imax=J AI_{max} = J\,A: an inner layer buried in a thick coil can only shed heat through the layers above it, so 2–3 A/mm² is typical for field coils; single-layer windings in free air tolerate much more.

Enamel thicknessThe enamelled diameter uses the approximation di≈1.04 d+20 μmd_i \approx 1.04\,d + 20\,\mu\mathrm{m}, close to heavy-build (grade 2) wire. Single-build wire is slimmer; triple-build fatter. Check the manufacturer's data for precise winding counts.